Peek-Frank · Source catalogue
Every document in the project folder (1), as catalogued by the fact-finder (facts.json). Click a column heading to sort. The documents themselves are not published here.
| Type | Year | Title | How read | Text |
|---|---|---|---|---|
| book | 1920 (second edition, McGraw-Hill; preface to first edition dated April 1915; second-edition preface dated July 1920) | Dielectric Phenomena in High Voltage Engineering (Second Edition) F. W. Peek, Jr. (General Electric Co., Consulting Engineering Dept.) SummaryA 325-page engineering treatise by F. W. Peek Jr. of General Electric, summarising his 1910-1916 laboratory and field work on high-voltage insulation. Its stated frame is that power transmission needs a dielectric (electric) field as well as a magnetic field, and that insulation fails when the dielectric stress (gradient, volts per cm) exceeds an 'elastic limit' [read: p.22-28 digest]. The best-known contribution is the law of visual corona: the surface gradient at which a wire starts to glow rises as the wire gets thinner, g_v = g_o(1 + 0.301/sqrt(r)) with g_o about 30 kV/cm peak, generalised for air density as g_v = g_o*delta*(1 + 0.301/sqrt(delta*r)). Peek reads this as 'air has a constant strength g_o, but a finite amount of energy of some form is needed to rupture it, so the gradient must hold at g_o over a finite distance 0.301*sqrt(r) cm from the wire' [read: p.65-68, 232-235]. The constants come from a two-group averaging fit ('Sigma-Delta reduction') to polished-wire and cylinder tests; the deep read found that 10 of 19 points were kept, the others discarded as 'probably in experimental error' without a stated criterion, that the algebra of the 'constant strength at a distance' reading is true of any g_v(r) curve, and that no calculation derives 0.301 or the square-root form from ion physics. Peek himself says the form of the rupturing energy 'has not been considered as it was unnecessary' for a working equation [read: p.234]. Companion fits give 31(1+0.308/sqrt r) for wires in cylinders, 27.2(1+0.54/sqrt R) for spheres, and approximate water and oil film constants. Chapter V (digest) describes the outdoor experimental Lines A and B (3/0 cable, 310 cm spacing, 109,500 cm conductor length) and the empirical corona-loss law p = a(f+25)(e-e_o)^2 fitted by the same group-averaging method, with c^2 found proportional to sqrt(r/s). Chapters VIII-IX give the working formulas in metric and English units (e_o = 21.1 m_o r delta ln(s/r) kV; p = (244/delta)(f+25)sqrt(r/s)(e-e_o)^2 x 10^-5 kW/km), irregularity factors, weather and altitude rules, a worked 100-mile three-phase example (e_o = 52.0 kV, which the deep read recomputed and confirmed to 0.2%), comparisons with measured losses on the Leadville (Faccioli), Pittsfield (Hendricks 1906) and Au Sable lines, and a corona-limit-of-voltage table. The deep read found minor misprints (A = 241 vs 244; a cell of Table LXXIX; 'critical voltage may also be decreased by grouping conductors', probably meant 'increased'). Other parts of the book cover sphere-gap and needle-gap spark-over tables (with the average sphere gradient 27.23(1+0.54/sqrt(delta R))), air-density and altitude corrections for insulators, oil and solid insulation (oil strength g_o = 36(1+1.2/sqrt r) kV/cm), fourteen design cases (graded cables, generator-coil corona, bushings, occluded air bubbles stressed 3x), and a data appendix. The appendix reports d.c. vs a.c. tests (d.c. breakdown about equals a.c. peak in air and oil; in varnished cambric d.c. is 1.27-2.59 times the a.c. peak, rising with thickness and time), a Paschen-law table (minimum about 350 V at p*x = 0.05 cm Hg cm), strength of thin air films (161-196 kV/cm at 0.0025 cm, about 35 kV/cm at 0.45 cm), and Peek's 1915 impulse tests with single half-sine waves from 55 to 900 kc: needle-gap impulse ratio from 1.00 up to 2.34, sphere gaps within about 5 percent (hence usable as impulse voltmeters), oil and solid ratios of 2-3.3, rain lowering 60-cycle insulator flashover 36-40 percent but impulse flashover only 2-3 percent, and impulse ratios up to 5.8 at air density 0.05. Peek attributes the impulse results to a 'dielectric spark lag': rupture needs a minimum energy and hence a minimum time [read: p.199]. The scan is a Google digitisation (library stamp dated Feb 18 1971) and the text layer is OCR on 324 of 325 pages; equations and tables are often garbled, so the deep readers worked from page images for the load-bearing formulas. The text states that all experiments are by Peek and GE helpers (H. K. Humphrey thanked in the 1915 preface), except named outside data: Watson (d.c. corona), Whitehead (Table IV compilation, 1917), G. R. Dean (sphere-field formulas), Dubsky (air films, 1914), Bennett (corona current oscillograms), Scott and Mershon (1898 Colorado), Faccioli, Hendricks. [Update after QE] Seven further deep reads were added (see how_read), so every chapter that carries a central claim has now been read from page images, not only digested. (1) Chapter V fitting chain [read: p.159-173, page images]: the quadratic law p = c^2(e-e_o)^2 is stated 'after trial' with no derivation; the Sigma-Delta (two-group) reduction of Line A test 36 used only the 6 highest of 14 points (the low points follow a different law and feed eq. 37). c^2 is printed x10^5 per km (scale confirmed from page image). The frequency offset (f+25) comes from the indoor Table LI (three conductors, one spacing 61 cm, 30-120 cycles); the deep reader's own fits of the outdoor Tables XLVIII-XLIX do not determine the -25. c^2 = 20,500 sqrt(r/s) x10^-5 comes from a 6+6 two-group fit of 12 of 21 outdoor tests (exponent -0.51 rounded to -0.50; nine tests dropped without a stated reason; RMS scatter 8.8% on the 12, 10.1% on all 21). A = 241 is 20,500/85 (60-cycle constant divided by f+25), so it joins two separate fits. The density correction c^2 proportional to 1/delta is called 'not satisfactory' by Peek himself [read: p.171]. The small-conductor law as printed has an extra term: c^2 = 20,500 sqrt((r + 6/s + 0.04)/s) x10^-5 per km (33a), valid for r >= 0.025 cm and s >= 15 cm [read: page image p.173], not (r+0.04)/s as in the digest. Eq. 37, p = q exp(-h(e_o-e)^2), has q (number of spots) and h (size of spots) defined, with listed values (q about 2.5-3.2e-6 per cm, h 0.021-0.030 for tests 30, 105, 103). The temperature series (Table LXII, Line A, 11 tests, -13 to +22 C) gives a line for 1/e_o that Peek draws to -273 C; the deep reader's fitted intercept is -241 to -283 C depending on points kept, and reducing all values to 25 C leaves a 1.4% spread. Humidity (Table LXIII, 10 tests): g_o constant to about 1.3%, but humidity and temperature are confounded. Wind, smoke, fog, snow, sleet: single occasions on Line A, figures only, no wind speeds, none used in a fit. Single-phase: the front matter states 'Tests were made on single-phase lines unless otherwise noted' [read: p.20] and the outdoor appendix says 'These tests were made on comparatively long single-phase lines out of doors' [read: p.286]; Line A has four conductors connected (1 and 3)(2 and 4), so the polarity along the plane is + - + - while Peek uses one spacing s = 310 cm. (2) The only out-of-sample test of the loss law in the book: Fig. 140, corona loss on two parallel wires (s = 67 cm, r = 0.127 cm, 200 cm long) at 100,000 cycles from an Alexanderson alternator, power by unity-power-factor tuning and hot-wire meters. Peek: 'This good check seems to show that the formula applies over a large range, but complete conclusions cannot be drawn from this small amount of data.' About five points. The deep reader finds the slope of the drawn curve matches (34a) with f+25 = 100,025 (about 29.8 W per kV^2 predicted), but the curve's onset (about 16 kV between lines) does not match e_d from (35a)/(36) (about 40 kV between lines), so mainly the frequency scaling is tested. Alexanderson was a GE engineer [memory, high]. (3) Energy-limited breakdown [read: p.199-202]: Hayden and Steinmetz (A.I.E.E. Trans., June 1910): gaps set to 30 kV at 60 cycles (air 0.95 cm, oil 0.16 cm); with a 100 kV transient the oil gap 'will not spark over if the energy applied to the circuit is less than 1.04 joules (4 amp.). For air the minimum energy is 0.45 joule (1.5 amp.)'. Peek adds 'The disruptive energy of oil seems to be about 30 times greater than it is for air' (p.148). The deep reader traced the 4 A (oil) and the 0.95 cm settings to the plotted curves; 1.5 A (air) is an interpolation (about 1.37 A on a straight line); the conversion from amperes to joules is not given and does not follow (1/2)Li^2 for one L (implied 0.13 H vs 0.40 H); the joules are circuit energy, not energy in the gap; the figures plot current, not energy, and show smooth drawn curves with no data points; they support 'spark distance independent of voltage' at low currents (0.25-0.5 A) but not for 2-4 A within the plotted range to about 105 kV; no time is measured. The same pages (Table LXIX, a different experiment by Peek) give 60-cycle versus impulse ratios 2.06-3.58 for oil and 1.35-1.83 for air, so an air gap can protect an oil gap but not the reverse. Stake: Steinmetz and Hayden were GE staff [memory, medium]; the paper itself was not read. (4) Chapter IV [read: p.115-153]: parallel-wire spark-over gradient is linear in spacing with intercept near 30 kV/cm (Table XIX fit 29.4); critical S/r averages 30.1 over nine wires (range 28.4-31.7); the sphere-gap law 27.23 delta(1+0.54/sqrt(delta R)) fits the cask data within 1.5% in 18 of 24 points (worst -3.8%). Peek's accuracy figures are three different things: a 2-3% commercial requirement, a 0.5% repeatability of readings (not a stated accuracy for grounded gaps), and 2% error for calculated curves. Impulse ratios: needle gap 1.20-1.94 (Tables XXXV, XXXVII), 6.25-cm sphere 1.04-1.10 (Table XXXVI) but the impulse voltage is itself read on a 25-cm sphere gap, so a sphere is calibrated against a sphere; calculated impulse voltages from circuit constants agree with sphere readings within 1-2 kV (Table XXXVII). Printing errors found by recomputation: Table XXXVIII delta 0.87 should be 0.77; worked example 2 (p.153) answer 65 kV should be about 74 kV. (5) Chapter III continued [read: p.93-114]: stranded cable m_v = 0.82 decided corona, 0.72 local corona (Whitehead, A.I.E.E. 1911; Table XVI); split conductors: 'the critical voltage is from 20 to 30 per cent. greater than that of a single wire containing the same amount of material' (Peek, p.98) and Whitehead 16% for three wires, 20% for four; so 'decreased' on p.246 is a misprint for 'increased'. Corona diameters by visual : glass lens : quartz lens = 1 : 1.6 : 1.9 (Whitehead 1912), so a large part of corona is ultraviolet; the stroboscope shows positive corona bluish-white and extended, negative red and localised, beaded on polished wire; corona-driven vibration: 'a pair of 20 mil steel conductors, 500 ft. long, were strung at about 10-ft. spacing ... vibrated, starting with a hardly perceptible movement, which in a few minutes had an amplitude of several feet at the center of the span' (fundamental period about 1 s; no date, place or voltage; repeated on short laboratory lengths, Figs. 83-84, motion 'rotary'); Peek reads the half-bright rotation as 'the effect of the stroboscope' at the 60 Hz supply frequency, which sits oddly with a 1 s fundamental. Bennett's oscillograms (A.I.E.E. June 1913) show a sharp positive hump at onset. (6) Chapter VII solid insulation [read: p.202-227]: 'It takes energy and therefore time to rupture insulation'; an insulator may survive nine impulses at three times the 60-cycle puncture voltage and fail on the tenth ('It may be that ...'; no experimenter, date or sample count); oiled pressboard 3.2 mm, 100 kV rapid 60-cycle: impulses to break 100 kV infinity, 140 kV 100, 150 kV 16, 155 kV 2, 165 kV 1. Time law g = g_s(1 + a/T^(1/4)) from one measured curve (14 layers of impregnated paper): fits with a = 0.49 (free exponent -0.257), but g_s = 13.0 is 12% below the 14.7 kV/mm implied by his own table, and for pressboard in oil (Fig. 153) the law with a = 0.5 fails by a large factor. Continuous high frequency lowers oil strength (6.7 kV/mm at 90,000 cycles against 17 at 60 cycles) while a single impulse raises it (39 kV/mm). Loss rises 'approximately' as e^2 and frequency, though the deep reader's slopes are 2.4-2.7. The a.c.-heating explanation rests on Rayner 1912 brass-versus-coated-terminal times, sample temperatures of 118-215 C at puncture, and loss against temperature; partial recovery after rest counts against pure heating. (7) Corona-loss data appendix [read: p.277-294, transcribed]: indoor tests 1B-56B, outdoor Line A and Line B tests. Table LV (12 tests) is outdoor only; 10 of its tests are on pp.287-294 (tests 86 and 77 are not). Voltages in the appendix are between lines (halve for e); losses are for the whole line length. Printing errors listed by the transcriber include several digit slips (tests 26B, 32B, 33B, 45B, 79, 102, 138); delta recomputed from the printed barometer disagrees with the printed delta for tests 138, 125, 126, 80, 79, which matters because corrected c^2 = c^2 x delta. The appendix names no operator, date or place; the Chapter V pages date test 36 to 6 Oct 1910 (inferred) and place the lines in a field east of which lay a city and a factory, unnamed. Key claims
Relevance: This is the only document in the project and it is the source of the 'Peek's law' of corona onset and the empirical corona-loss formula still named after him. It matters here because it states the energy-storage distance idea as a physical hypothesis while presenting the constants as fits, and because the book documents its own experimental method (polished wires, dark room, group-averaged constants) in enough detail to be examined. It is also the primary record of Peek's 1915 impulse tests, an early quantitative account of time lag in breakdown. Interested-party note: Peek worked for General Electric, which had a commercial interest in high-voltage transmission equipment; the preface credits GE's Consulting Engineering Department for the experiments. Interested-party note on the added material: the Hayden-Steinmetz (1910) minimum-energy data and the Alexanderson 100 kHz loss check both come from GE staff; no non-GE test of either is in the book. Mainstream conflict: Broadly none on the practical formulas: Peek's law remains in use as an engineering estimate [memory, medium confidence]. Points where the text departs from or lags later physics: the 'energy-storage distance' and 'condensed gas film' discussions pre-date the modern ionization and streamer treatment of corona onset; mainstream gas-discharge physics treats breakdown time lag as statistical lag plus formative lag, and a limited-energy circuit as unable to sustain a discharge into an arc, which is a different reading from Peek's dielectric 'minimum energy' [memory, high; not web-checked here]; 'the ether' wording (gamma rays 'probably ether waves', p.230) belongs to pre-relativity physics; 'electron has the same mass as the hydrogen ion' (p.230) contradicts the 1/1800 ratio given in the same passage; the p.246 statement that grouping conductors 'decreased' the critical voltage conflicts with Peek's own data on pp.96-98 (grouping raises it by 16-30 percent) and is read as a misprint. The small-gap high-strength result is explained by Peek's energy distance; the Paschen curve explains it as a point near or right of the minimum (p x = 1.9 torr cm at atmospheric pressure and 0.0025 cm), not the left-hand branch [calc]. No claim here requires new physics. | digest (all 8 chunks, PDF pp.1-325) + deep reads from page images (PDF pp.60-92 Ch. III visual corona; pp.93-113 Ch. III cont.: stranding, split conductors, photography, stroboscope, vibration, Bennett; pp.115-138 Ch. IV first half: parallel-wire and sphere-gap spark-over, density law; pp.139-153 Ch. IV second half: impulse ratios, rain, altitude, Hayden-Steinmetz passage, worked examples; pp.154-189 Ch. V corona loss: full fitting chain, Lines A and B, indoor line, Fig. 140; pp.196-202 end of Ch. VI: oil energy distance, Figs. 147-151, Table LXIX; pp.202-227 Ch. VII solid insulation; pp.227-251 Chs. VIII-IX electron theory and practical formulas; pp.277-294 corona-loss data appendix, transcribed; pp.295-311 d.c., air-film, Paschen and impulse appendix). Digest only: front matter and Ch. I-II (pp.1-59), Ch. VI pp.189-195 (oil, apart from Fig. 140 on p.189), Ch. X design cases (pp.252-276) and index (pp.312-325). | partial |