Physicist review: HiIQ-Youtube ("Partnered Output Coils", Chris Sykes / hyiq.org)
Role: PhD physicist (Step 2). Tags: [read] from a document, [web] with URL, [memory] with confidence. Reader: self-taught, undergraduate level.
What I read and did not read
- [read] facts.json, claims.md, the single digest and the whisper transcript. There is no deep/ folder for this project (the one document was judged digest-sufficient), so I read the primary text myself.
- [read] The Investigator's source of the video, "Guidelines to Bucking Coils" v2.7 (26.02.16), text layer, all 49 pages of text (research/files/hyiq-Guidelines-to-Bucking-Coils-2016.pdf), and its notes in research/. [read] "Self-Assisted A Vector Potential Oscillation" (2011), first part of the text layer.
- NOT done: I did not view the video frames, the Guidelines' figures, the scope traces, or the saved overunity.com page, and I did not see any of the later pages of the 350-page forum thread. Conclusions about measurements therefore rest on the text layers and on the Investigator's notes. The Cyril Smith paper and the gratisenergi.se page were not readable by anyone in this review.
- Web checks (2 of ~6 used): a search for Cyril Smith's "Bucking Coils produce Energy Gain" found no readable copy [web: search results only, no matching page]; a search for independent VTA tests found only descriptions and claims, no independent measurement [web: https://www.scienceforums.net/topic/32309-vacuum-triode-amplifier-floyd-sweets/ and KeelyNet text files]. Both checks are negative for "found", which is not evidence either way.
Who, what, stakes
The video "How Partnered Output Coils Work Together - Its NOW up to YOU!!!" is by Chris Sykes (forum name EMJunkie), hyiq.org and the aboveunity.com forum [web, per the Investigator: https://www.youtube.com/watch?v=Z-V1z2TdQJA]. He runs both the project and the forum where it is discussed. "Above unity" labels there are his and his community's characterisation. He is also candid in his own text: "For every one device that works, expect 10 devices that don't"; "I may be wrong and it may work a totally different way"; "I believe I still don't quite fully understand this section" [read: Guidelines v2.7]. In 2011 he wrote twice that his first device "is below unity" and "not an Over-Unity Device" [read: Self-Assisted paper, per the Investigator and my read of the opening].
The mainstream view, stated fairly (needed for every claim)
- Faraday's law: an EMF (voltage source) appears around a loop when the magnetic flux through it changes: EMF = -N dPhi/dt. N is the number of turns, Phi the flux.
- Ideal transformer (tight coupling, no loss): both windings see the same flux, so V2/V1 = N2/N1. Power in equals power out, so I2/I1 = N1/N2. A 1:3 step-up gives three times the voltage and one third the current.
- Lenz's law is the minus sign. It is not an extra force that engineers must "get around". When a secondary delivers power, its current's magnetic force (ampere-turns, N2 I2) opposes the flux. The primary must then draw extra current (N1 I1 grows) to keep the flux. That is how the load's power reaches the primary: it is the energy accounting, not a defect.
- Coil pairs that "buck" (oppose) each other are common: humbucking pickups, buck-boost transformers, noise-cancelling and MRI shim coils. Opposing fields cancel in space (sum of vectors is zero). Energy in the field does not vanish; two opposed coils have a net inductance that is small, and the energy goes elsewhere (heat, load, the partner coil). [memory: high]
Claim 1. A primary with two "partnered" secondaries whose fields sum to zero works as a transformer where the load's Lenz field is cancelled by the pairing.
Source: [read: video transcript; Guidelines "Lenz's Law" section]. Sykes's wording: with a loaded transformer "there is a NET ZERO Magnetic Field... the Ampere Turns on the primary are equal but opposite to the Ampere Turns on the secondary"; he reads this as Bearden's wave/anti-wave and wants to "eliminate or reduce this Secondary Induced Magnetic Field" so that "there would be no Reflected Power on the primary".
a. Mathematics. Sykes gives almost no equations for the device. His own description of an ordinary loaded transformer (primary and secondary ampere-turns equal and opposite, net field near zero) is correct, and it is the standard ampere-turn balance [memory: high]. But he draws the wrong lesson from it. The ampere-turn balance is exactly how the load power gets back to the primary; it is the thing he wants to abolish. The "wave/anti-wave" analogy to noise cancelling is not a power analogy: a noise-cancelling headphone cancels sound at the ear by spending extra power in a speaker.
Worked reasoning (my derivation, not in the sources). Put two secondaries A and B on one core, each in its own loop with its own load, wound oppositely so their terminal voltages are opposite. Each secondary delivers power to a load, so each current's magnetic force opposes the core flux change (Lenz, per coil, regardless of winding sense). Both oppose; they add, they do not cancel. If instead the forces really cancel (A's and B's ampere-turns equal and opposite), then one of the two coils is driving current against its own induced EMF, i.e. it is absorbing power from the other. This is exactly Jensen's own words that Sykes quotes: "each secondary winding [acts] as the primary winding for the other secondary winding when an output current is drawn" [read: Guidelines]. So the pair is a transformer between A and B. The primary no longer sees "A's load" because A's output goes into B, not because power appears from nowhere. The useful (net) output is then the difference between what A produces and what B absorbs, plus the loads they feed.
Sykes admits the cancellation is incomplete ("Total Cancellation is also impossible", the wires cannot share the same space) and that the field "does not mean there is no longer any Magnetic Field", it is confined to the coil space [read: Guidelines]. Internally the description is loose but not contradictory; it is incomplete (no circuit equations, no mutual inductances, no phases).
b. Consistency with experiment. Cancelling fields in space: consistent (Established; humbucking, bucking coils, MRI). Reduced reflected load on the primary because the secondaries oppose each other: consistent (coupled-coil theory, Jensen's description). Reflected load vanishing while net power is delivered to a load: inconsistent with all measured transformers and generators, as it would be a perpetual motion machine of the first kind [memory: high]. Sykes himself states that if Lenz's law could be bypassed "every Generator on the planet could be a perpetual motion machine of the first kind" [read: Guidelines], and answers by saying a generator "is not an isolated system".
c. Tested? By Sykes: a rotor with magnets passing a bobbin wound with partnered coils, result "No or next to no Lenz's Law" while electricity is generated; no numbers given [read: Guidelines]. His 2011 device was stated to be below unity [read]. Third parties: overunity.com thread 15395 (350 pages, 305K reads by Sep 2015; the forum is now offline) is the main public record; only page 1 was read by the Investigator [web: Wayback]. Third-party build "I made a Bucking Coils Transformer and was dissapointed when I found no Free Energy" is known from one Google snippet of gratisenergi.se (page 404 now): documented in one source, no second source found, page not retrievable [web per Investigator]. Cyril Smith, "Bucking Coils produce Energy Gain" (2015): title and first line only ("There are many claims of overunity for systems that employ bucking coils") [web per Investigator]; content unknown. Energetic Forum "Bucking Coil Inverter": a builder lights a 6 W LED, no input/output measurement known [web: Google snippet per Investigator]. No controlled, neutral, instrumented input/output power test of a partnered-coil device is on record in the material found. No replication in the scientific sense (independent, measured, reported) was found.
d. If true (strong form: net power out without extra input power), conservation of energy and Poynting's theorem (the field energy balance of Maxwell's equations) would have to change; in particular, the Lenz sign, which is a consequence of them. The weak form (a bucking pair re-routes reactive power between coils) requires no change.
Verdict (split): - Weak form (opposed secondaries cancel their fields in space, shifting the reflected load between coils): Established. - Strong form (this removes the Lenz/reflected load without extra energy input, giving net gain): Never properly tested (no neutral instrumented test on record; the community tested it informally and in a forum thread not fully read) AND Refuted by calculation in the energy-budget sense: any net surplus is excluded by conservation of energy; the only open matter is whether a given measurement had an artefact. Not dismissed without testing, though the tests found are informal.
Claim 2. With each partnered output coil at 3 times the primary's turns, the voltage is stepped up 1 to 3 in each output coil.
a. Consistent: V2/V1 = N2/N1 [read: Guidelines states ideal-transformer rules correctly]. b. Consistent with every transformer measurement, provided coupling is tight. Caveat: Sykes says loose coupling and gapped cores work "better" for his device [read]. With loose coupling the ratio is below 3:1 (it becomes k N2/N1 with coupling coefficient k, plus loading). Also, in a bucking pair on a common flux, the terminal voltages are 3:1 in magnitude but opposite in sign, so they cannot be wired in series without cancelling. c. Tested everywhere; replicated for 150 years [memory: high]. d. Nothing. Verdict: Established (ideal/tight coupling); qualified for loose coupling.
Claim 3. Current is not stepped down as the voltage is stepped up.
Source: [read: video; Guidelines]: "Ideally, these devices work with a Step Up configuration. 1:3 is a common Ratio... Current, as you may think, is not stepped down as a result of the Voltage being stepped up", directly after he states (correctly) 240 V x 1 A = 24 V x 10 A [read: Guidelines].
a. As stated it is ambiguous, and the ambiguity is the whole issue. (i) The output current is simply the load: I_out = V_out / R_load. Nothing steps it down; that is trivially true for any transformer, which is why a 1:3 step-up with a 10-ohm load makes 3.6 A at 36 V from 12 V. (ii) Compared with the primary current: the ideal transformer requires I_in = 3 I_out. The claim means the second, and then conflicts with power balance unless input power is not the product of input volts and amps (a measurement problem) or extra energy enters. Worked numbers (my calculation): primary 12 V RMS. Each output at 1:3 gives 36 V. Load 10 ohm each: I = 3.6 A, P = 36 x 3.6 = 129.6 W each, 259.2 W for the pair. Power conservation then demands at least 259.2 W in (ideal), i.e. 21.6 A at 12 V. If the primary draws 1 A, input is 12 W (at unity power factor): output would exceed input by 21.6 times. (A "1 to 100" input:output ratio quoted on a Prezi page from an overunity.com post is a lead; I could not read the post.) At 36 V and 10 ohm the secondary coil wire, core and leakage also dissipate power; none of these helps. b. Inconsistent with the Establishment (every transformer, generator; the 98-99 percent efficient machines Sykes himself cites). Sykes's own text does not give a single power measurement. Where input power is reduced he explains it by "feedback" raising the input coil's impedance [read: Guidelines]; if true that is a lower input at the same output, which is the same energy violation and must be shown with an input power measurement that accounts for phase (apparent power V x I is not real power; with a reactive load or resonant input the product V x I can exceed real power by a large factor). A frequent failure in the field: measuring DC supply power with a switching input; the Investigator found a reply on overunity.com (#3589) warning how easy it is to "screw up an input power measurement involving a DC supply" [web per Investigator]. c. Tested by? No instrumented test found. Replications: none found with data. d. Conservation of energy would need to be reformulated for electromagnetic systems; no one has shown the need. Verdict: Refuted by calculation if read as net current gain at the input side (power balance); the trivial reading (output current is set by the load) is Established. Not tested with measurement in the record found.
Claim 4. Feedback and feed forward in the partnered output coils can increase the "Separation of Charge Carriers", and "Excess Output Energy can be obtained" (corrected caption; see Corrections).
Source: [read: video frame caption per the Investigator; Guidelines]. His principles: "Induction is the Separation of Charge Carriers" by the Lorentz force; "Lenz's law is the Result of drawing Current from the already Separated Charge, not the cause" [read].
a. "Separation of charge carriers" is undefined as a measurable quantity; "feedback and feed forward" is not specified (which coil, what phase, what gain). I found no equation connecting them to output energy. His physical statements contain errors, noted in "Errors in the background claims" below. The Lorentz-force picture of induction is legitimate and standard: motional EMF = B v l comes from the force on charges, and Cohn's 1949 paper that he cites treats motional and transformer induction separately [read: Cohn p.1, per the Investigator]. Cohn does not support a gain; his page 1 warns that confusing the two laws produced "innumerable d-c generators without moving contacts which have been invented (and do not work)" [read]. b. The phrase "excess output energy" contradicts conservation of energy unless an energy source is identified; he names the aether and the "Dirac sea" [read: Guidelines; hyiq.org via Wayback] without a measurement or a calculation. Sykes later says "I found out that only some of this is correct... there was no new form of Energy" [read: Guidelines], which somewhat softens the claim. c. Tested by? Self-reports. His charge-time experiment (bifilar 650 microseconds against 75 ms) shows only that a coil with high inductance charges slowly. L/R time constants: with L = 0.231 H and R = 7.8 ohm, tau = L/R = 29.6 ms, so 75 ms is about 2.5 tau; non-inductive 0.24 mH gives 31 microseconds (my calculation from his component values), so 650 microseconds probably reflects stray capacitance or the measurement setup, a result I could not check without the figure. It does not show that "the magnetic field slows charge flow rates"; it is the back-EMF, -L di/dt. This is Established mainstream physics and it does not bear on net energy. d. Would require a new energy source and a revision of Poynting's theorem; no evidence offered. Verdict: Not testable as stated (charge-carrier separation, feedback and feed forward are undefined); the "excess energy" part: Never properly tested (no measured input and output on record).
Claim 5. The technique is cheap to try (about 20 dollars) and viewers should build and share it.
Not a physics claim. The Guidelines list low-cost parts (function generator $14.99, amplifier $12.67, coils $15.50 each) [read], so the total is nearer $60 than $20 for the setup he describes; the video says "from around 20 dollars". Verdict: Established as a statement about cost (an invitation); the physics test cost is low, and the lack of a published, controlled measurement is not for lack of cheap equipment, but a measurement needs a power meter or scope with phase.
The Investigator's findings, weighed (kept whatever the verdict)
- Guidelines v2.5 / v2.7: the source of the video. It shows the claims 2 and 3 side by side, with the correct ideal-transformer calculation beside the statement that "current is not stepped down". Weight: highest relevance; it is the inventor's own account and carries no power data.
- Self-Assisted paper (2011): states "below unity". Honest by the author; helps the reader understand that "above unity" arrived later without a stated measurement. A progress claim from 2011 to 2015 with no documented data in between in the files found.
- Prior art listed by Sykes (Sweet VTA, Jensen UDT, Koenig US4806834, Markov, Melnichenko, Frolov, Cook US 119,825). These are his attributions, unverified. I could find no independent measurement of the VTA [web: scienceforums.net and KeelyNet texts]; claims for it come from Bearden, Manning, Sweet associates (interested parties promoting the technology). The Cook patent and Koenig patent were not read. Sweet's quote in the Guidelines that a conductor would carry "10 times more current at the same temperature" contradicts Joule heating P = I^2 R (R set by the material at a given temperature) [read: Guidelines]; if the current is ten times larger the heat in the same wire is 100 times larger. That is Refuted by calculation.
- Cohn 1949: cuts both ways, stated above.
- overunity.com thread 15395 and the Prezi "1 to 100" quote: leads, unread. This is where the claim was tested publicly by many builders; the lack of any widely-cited measurement report in the material found is not conclusive. The thread's later pages and the Energetic Forum thread are the records most likely to hold actual measurements.
- gratisenergi.se "no Free Energy" report and Cyril Smith (2015): one snippet each; they are evidence against (the first) or unknown (the second), not to be dismissed or relied on until the pages are read.
- The record going dark (hyiq.org, aboveunity.com not responding on 2026-10-06; overunity.com now a domain for sale; last full capture of the Guidelines 2024-10-27) [web per Investigator]. Competing explanations: hosting lapse (Google still lists pages; aboveunity threads dated Dec 2025 suggest recent activity), migration, or withdrawal. Not a physics matter; a recheck would settle it.
Errors in the background claims (kept for the reader to weigh)
- "A is the Electric Component of the Magnetic Field and Phi is the Magnetic Component": A is the vector potential and Phi is the flux (in the text, he also uses Phi for flux); the mainstream names are different [memory: high; read: Guidelines]. He equates the two uses.
- "Mechanical Energy is NOT the Source of the Energy Generation": in a generator the shaft work is the source; with open terminals the shaft turns almost freely (Lenz drag is zero when no current flows), and that is what energy conservation predicts [memory: high]. Sykes's own example (a loaded generator versus an open one) fits the mainstream account.
- "CRT magnets squeezed to nearly zero": field is small only at points near the pair; the stored energy is not destroyed (the magnets resist being pushed together) [memory: high].
- "Bloch wall" is a magnetic-domain boundary in a ferromagnet; Sykes uses it for the moving boundary of the field in a coil, which is different [memory: medium; I did not check a source].
Corrections to Step 1
- Claim 4 in claims.md and facts.json ("separation of the input coil") is a transcription error; the on-screen caption reads "Seperation of Charge Carriers and Excess Output Energy can be obtained" (the Investigator's frame reading; I did not view the frames). The digest's "(or field strength)" is the digester's guess and is unsupported.
- "Jaker" is "Jaycar" (Investigator's reading of frames).
- The Source gap in claims.md is largely closed by the Guidelines v2.5/v2.7, which are the written source of the video. It remains open for the video's images and the measurements (none found in text).
- claims.md claim 3 and facts.json's mainstream_conflict are accurate but incomplete: the ambiguity between "output current set by the load" and "current gain from input to output" must be separated (my claim 3 above).
- facts.json states the opposing-field arrangement "is not in itself in conflict with standard electromagnetism". This is right for the geometry, but the video's claim that pairing cancels the Lenz load for a loaded, net-power-delivering device is a stronger statement and conflicts with energy accounting; a loaded coil whose field is cancelled is being fed by its partner.
- facts.json lists no entry for the Guidelines, the Self-Assisted paper or Cohn (not in the project folder, so correct); the review adds them as Investigator documents.
- No deep reads exist for this project; the single transcript was sufficient for the 5 claims, but the central measurement evidence (figures, scope traces, the forum thread) has not been read by anyone. That is a gap, not an absence of data.
Summary of verdicts
- Pairing cancels Lenz load: weak form Established; strong form Never properly tested and Refuted by calculation (energy budget).
- 1:3 voltage in each output: Established.
- Current not stepped down: Refuted by calculation (as input-to-output current gain); trivial reading Established.
- Feedback and feed forward give charge-carrier separation and excess energy: Not testable as stated; "excess energy" Never properly tested.
- Cheap and shareable: Established as a cost statement (not a physics claim).